Nano Cloaking Film passed ASTM: E84-19a for Surface Burning Characteristics of Building Materials
ASTM E84 Certification Requirements:
The requirements for ASTM E84 certification can be found throughout the building code for various products. Some products, such as those identified in Chapter 14 - Exterior Walls, require certification by reference to labeling requirements of 1703.5 (2018 International Building Code). Fire-retarded treated wood, and foam plastics are required by their specific chapters, Chapter 23 and 26, respectively, to be certified by an approved agency. Certification is not required by the building code for interior finishes but does require testing in accordance with ASTM E84. Many manufacturers of interior finishes chose to certify their products through an approved agency for ease of approval and demonstration of an elevated quality control system for their products.
ASTM E84 Scope:
This 10-min fire-test-response standard for the comparative surface burning behavior of building materials is applicable to exposed surfaces such as walls and ceilings. The test is conducted with the specimen in the ceiling position with the surface to be evaluated exposed face down to the ignition source. The material, product, or assembly shall be capable of being mounted in the test position during the test. Thus, the specimen shall either be self-supporting by its own structural quality, held in place by added supports along the test surface, or secured from the back side.
Applicable Products:
Building Materials, Wallcoverings, Insulation Materials, Panel Products, Paints, Adhesives, Sealants and Coatings, Interior Finishes.
Related Standards:
ASTM E84, UL 723 and NFPA 255 utilize the same equipment and test method. All three are essentially the same test and are often referred to interchangeably by the building code.
Test Procedure:
An ASTM E84 test is conducted by placing a 24” wide x 24’ long sample into a Steiner Tunnel wherein the test is administered through the use of two burners which provide 89kW of energy. During the 10-minute test, the sample is mounted on the ceiling under a removable lid, and a forced draft is provided in order for the movement of air and products of combustion within the tunnel, and to the exhaust/scrubber system.
The Flame Spread Index (FSI) is calculated with data recorded from flame travel that is observed through the windows located on the side of the chamber. The computer software records the flame-spread position during the test 10-minute test. The area under the flame spread curve is used to calculate the Flame Spread Index.
The Smoke Developed Index (SDI) is calculated with data recorded from a photo meter system that consists of a light source, photocell and specialize electronic equipment. The light beam travels vertically through a vent pipe and the computer software records the light obscuration as the smoke travels through the light beam path during the test. The smoke area under the smoke curve is used to calculate the Smoke Developed Index.
End Result:
According to ASTM, the purpose of this test method is to determine the relative burning behavior of the material by observing the flame spread along the specimen. Flame Spread Index (FSI) and Smoke Development Index (SDI) are reported for a given sample. However, there is not necessarily a relationship between these two measurements. FSI is the measurement for the speed at which flames progress across the surface of the sample, while SDI measures the amount of smoke a sample emits as it burns. Code officials, designers, and architects use the FSI and SDI results to determine if the product meets applicable building codes requirements based on the results of this test. Most commonly, results are correlated as shown in the chart below for interior finishes (Reference Chapter 6 of the International Building Code).
Classification | Flame-Spread Index (FSI) | Smoke Development Index (SDI) |
Class A (also referred to as Class 1) | 0-25 | 450 Maximum |
Class B (also referred to as Class 2) | 26-75 | 450 Maximum |
Class C (also referred to as Class 3) | 76-200 | 450 Maximum |
Click the following screenshots to download the PDF documents: